UPS Warranty. Resource Library. Select a category, choose a Product Family, then select from the list of available documents. Sign In Email: Hash Token:. Need to Register? User is Active. If your web browser's integrated pop-up blocker is enabled, it may prevent the some features on this site from functioning normally. If you have an issue completing the registration process, please disable your browser's pop-up blocker or ensure that www. User Active Yes No. Download Registration Thanks for registering.

Daily Status Report : 7. Mail Receivers 8. Test Email Configuration 0. The settings may be viewed and changed from this screen.

Temperature Group — The SNMP Communities lists the status and configuration of access rights that are currently granted and the applicable level of access. Community String: NMS community string. Selecting this option restores all RemotEye II card settings to its original default values.

Hardware Setup Telnet configuration is accomplished through a network link. This is typically only necessary when RemotEye II is using its default address. Consult operating system documentation pertaining to the addition of network routes for instruction.

Hardware Setup Web configuration is accomplished through a network link. If unable to access the RemotEye II due to a firewall, contact the network administrator for information on bypassing the firewall of the LAN.

Non-DHCP users continue on to step b. DHCP users may skip steps b to d. The UPS measured parameters are listed below and are allowed only to be read. This page will refresh automatically at a user- defined rate.

Page 51 Battery Parameters This page provides the battery status and battery run-time information. This page will refresh automatically at a user-defined rate. Output Status This field shows the status of the output. UPS Attached Devices This field allows the administrator to assign a description of load devices that attached to the UPS or to view the current setting. Page 57 Number of Batteries in Series This field allows the administrator to configure the total number of batteries in series of the UPS system.

Number of Batteries in Parallel This field allows the administrator to configure the total number of batteries in parallel of the UPS system. The available menu options will be a function of the UPS type. Last Test Start Time This field shows the start time of the last battery test. This value is displayed in the hh:mm:ss hour format i.

Index This field shows the battery test schedule. Test Day This field allows the administrator to set the day of the week that the battery test is to be performed or to view the current setting.

UPS Event This field shows the event that to which is assigned a shutdown action Action This field allows the administrator to set a course of action to be taken in the event of a fault. Page 62 Different Events Input Power Failure This field shows the action taken upon detection of an input power failure. Default: Warning. Battery Low This field shows the action taken upon detection of a battery low condition.

Event Index This field shows the reference number for the shutdown or restart event. Output Shutdown Date This field allows the administrator to configure the specific date of the UPS output shutdown or to view the current setting. Page 65 SMTP administrator. Example, tic. Otherwise, this field can be 0. Page 66 Daily Status — Daily History log and Events log will be sent to the email recipients at the designated time. Page 67 For the contact alarm sensors, the hysteresis can be used to adjust the sensitivity of an alarm.

The alarm will be active or inactive only after the alarm stays in the same state for the duration of the hysteresis value in seconds.

For example, if the hysteresis is 5 for an alarm, the alarm will NOT activate until the same state has persisted for 5 seconds. Within the parameters, the Primary Time Server and the Secondary Time Server can only send out the correct time information to a client that has the Shutdown program installed. Default Language This field allows the administrator to set the default language: English or Japanese. In addition, it allows the administrator to restart or reset the RemotEye II.

Index This field shows the index numbers of the table entries. Page 74 Setting options are: None : Traps are not being received. Description This field shows the customer description string. Comprehensive Page This field allows the administrator to set the refresh rate in seconds of the Comprehensive View menu or to view the current setting.

Battery Group Page This field allows the administrator to set the refresh rate in seconds of the Battery Parameters menu or to view the current setting. The log messages are displayed in chronological order and are used to help detect and diagnose problems with the RemotEye II. For each of the UPS parameters, the minimum, maximum, and average values are shown in each of the records. The existing values are overwritten when the maximum number of entries has been reached.

Specific log data may be cleared by the user or the entire log data record may be cleared after saving the. Monitor — Displays the UPS key parameters graphically. This screen displays the UPS history log as a line graph. By default, all of the UPS parameters will be displayed on the same graph. By default, all the UPS parameters will be displayed on the same graph. Toshiba Enterprise v1. UPS Warranty. Select a category, choose a Product Family, then select from the list of available documents.

Sign In Email: Hash Token:. Need to Register? User is Active. If your web browser's integrated pop-up blocker is enabled, it may prevent the some features on this site from functioning normally.

If you have an issue completing the registration process, please disable your browser's pop-up blocker or ensure that www. User Active Yes No.